Ko'rishlar: 229 Muallif: Sayt muharriri Nashr qilish vaqti: 2018-12-14 Kelib chiqishi: Sayt
loyihalash va o'rnatish Havodan suvga issiqlik nasosini isitish va sovutish tizimlarini juda talabchan. Kichkina xatolik keyingi operatsiya davrida muammolarga olib kelishi mumkin. For this reason, we consult engineers who have a lot of experiences in the design and installation of air source heat pumps, and share practical tips with you for your reference.
Tizimda iloji boricha yumshoq suvdan foydalaning.
Ko'p odamlar isitish va sovutishni o'rnatishda suv sifati muammosiga katta e'tibor bermasligi mumkin havodan suvga issiqlik nasosi tizimi. Ba'zi hududlarda suvda kaltsiy va magniy ionlarining nisbati juda yuqori. When they increase in the system, they may cause blockage in the pipes, Y-type filters, water pump and so on, which seriously affects the performance of the heat pump.
Bundan tashqari, qishda harorat nisbatan past bo'lgan joylarda ma'lum miqdorda antifrizli suyuqlik yoki spirt qo'shilishi kerak. Antifriz suyuqligi odatda ko'rsatmalarga ega. Agar spirtli ichimliklar ishlatilsa, 99 ° sanoat spirti tavsiya etiladi. Spirtli ichimliklar miqdori haqiqiy vaziyatga va tizimdagi aylanma suv hajmiga qarab sozlanishi mumkin. For example, the circulating water amount in the system is 100L, plus a kilogram of alcohol, the alcohol content of the water is basically 1%, and then the freezing temperature of the water is -1℃. Ko'pgina hududlarda qishda harorat past bo'ladi. Agar foydalanuvchilar uzoq vaqt davomida zamin isitishidan foydalanmasalar yoki tunda elektr quvvati uzilib qolsa, quvurlar yoki bloklarning muzlashi va yorilishiga olib kelishi oson. Shuning uchun ma'lum miqdorda antifriz suyuqligi yoki spirtli ichimlik kerak.
Fan bobinlari ikki tomonlama valflar bilan jihozlangan bo'lishi kerak.
Nima uchun tizimda fan lasan va uch tomonlama shar vana bo'lishi kerak? If only two-way ball valves are used, when the user seldom uses fan coils but only opens one or two, the resistance of water in the system is very huge, which easily causes the vibration of the pipelines and then produces noise.
Iloji boricha konservalangan dvigatelli suv nasoslari yoki ko'p bosqichli markazdan qochma suv nasoslaridan foydalaning.
Isitish va sovutish tizimi uchun to'g'ri turdagi suv nasosini tanlash juda muhimdir. Odatda, yopiq konturli suv nasos tizimi tavsiya etiladi. The pressure of each point in the closed loop system is equal, so there is no need to consider the drop of water pipe but only the main force of pipe bend and length. Shunday qilib, kuchaytirgich o'rniga konservalangan motorli nasos yoki ko'p bosqichli santrifüj nasosdan foydalanish tavsiya etiladi.

Barcha quvurlar izolyatsiya qilinishi kerak.
Whether we are installing a heating and cooling system at home or doing a hot water project, the indoor pipes, especially the pipes inside the ceiling, must be insulated. Isitish va sovutish uchun ikki tomonlama ta'minot tizimi uchun kondensat drenaj quvurlari kondensat oqmasligi uchun izolyatsiyalangan paxta bilan yopishtirilishi kerak.
Avtomatik egzoz valfi tizimning yuqori qismida o'rnatilishi kerak.
Agar suv idishining joylashuvi yaxshi aniqlanmagan bo'lsa, biz uni haqiqiy vaziyatga qarab aniqlashimiz kerak. Agar uni tepaga o'rnatish mumkin bo'lsa yaxshi bo'ladi. But in some cases, the water tank can only be installed on the ground or somewhere lower, so the exhaust problem should be considered for the system.
Asosiy tizim quvurlari to'g'ri bo'lishi kerak.
Butun tizimning asosiy quvurlari to'g'ri bo'lishi kerak va oqim yo'nalishi bo'ylab bir oz tepaga ko'tarilishi kerak. That is to say, the inlet pipe should be slightly raised while the return pipe should be slightly lowered, so as to facilitate the discharge of air in the pipelines. Magistral quvurlar U shaklida bo'lmasligi kerak, bu havo tiqilib qolishiga olib keladi va yumshoq ulanishlarni o'z vaqtida ishlatish ham mumkin emas.