Ko'rishlar: 2785 Muallif: Sayt muharriri Nashr qilish vaqti: 26-11-2019 Kelib chiqishi: Sayt
So'nggi yillarda havodan suvga issiqlik pompasi asta-sekin ko'plab oilalar uchun qishki isitish tanloviga aylandi. However, compared with traditional heating modes, people's knowledge of air source heat pump heating is not enough, and there are still some doubts about its use. Ushbu maqola havo manbali issiqlik pompasi (ASHP) bilan uyni isitish uchun tavsiya etilgan xona haroratini aytib beradi.

Havodan suvga issiqlik pompasi an'anaviy issiqlik manbasidan farq qiladi. ASHP bilan uyni isitishning turli usullari mavjud, masalan, radiatorlar, polni isitish, fan batareyalari va boshqalar, ular ASHP bilan ishlatilishi mumkin. Due to the dual function requirement of cooling in summer and heating in winter, SPRSUN provides air to water heating and cooling heat pumps that can combine floor heating with fan coils. Hozirgi vaqtda isitish / sovutish moslamalari katta qulaylik va energiya tejash afzalliklari tufayli foydalanuvchilar va bozor tomonidan yuqori baholanmoqda.
ASHP da qanday xona harorati o'rnatilishi kerakligini tushuntirish uchun isitish va sovutish moslamasidan foydalanamiz. Siz xona harorati va suv haroratini sozlash uchun kontrollerdan foydalanishingiz mumkin.
At the first time when the air heat pump is used for room heating, the indoor temperature adjustment should follow the gradual step by step heating principle. Dastlabki ishga tushirish vaqtida suv harorati 35 daraja Selsiyga sozlanishi mumkin. 24 soatdan keyin harorat 40 ℃ ga o'rnatiladi. 48 soat ichida 45 ℃ ga ko'tariladi. Keyingi bosqichda haroratni 45 ℃ da barqarorlashtirish mumkin. Birinchi isitish vaqtida xona harorati nisbatan sekin ko'tariladi, shuning uchun eshik va derazalarni yopish va sabr-toqat bilan kutish yaxshidir.
Umuman olganda, inson tanasi uchun eng mos muhit harorati 18 ℃ dan 22 ℃ gacha, bu individual farqlarga qarab o'zgaradi. Therefore, we recommend that when using ASHP for heating (floor heating or fan coils), the indoor temperature in winter should be set at 18-20℃, and the water temperature should be set at 38-40℃; yozda sovutish paytida xona harorati 22-28 ℃ ga, suv harorati esa 14-18 ℃ ga sozlanishi kerak. Agar isitish tizimi radiatorlardan foydalansa, suv harorati haqiqiy ehtiyojlarga qarab yuqoriroq o'rnatilishi mumkin.
ASHP uyni isitish uchun ishlatilsa, foydalanuvchilarga yuqori xona haroratini o'rnatish tavsiya etilmaydi. First, it affects health: the higher the set indoor temperature is, the greater the indoor and outdoor temperature difference will be, which may lead to large fluctuation of blood pressure and 'overburden' of coronary artery, resulting in coronary heart disease.
Shu bilan birga, yurak-qon tomir tizimi yurak va o'pkaga katta ta'sir ko'rsatadi. Issiq va quruq xonada qolish ko'pincha vahima, ko'krak qafasidagi siqilish, o'pka yurak kasalligi va yurak disfunktsiyasiga olib keladi. Ikkinchidan, energiya samaradorligi pasayadi: ASHP energiya tejash afzalligi bilan mashhur. Xona harorati juda yuqori o'rnatilgan bo'lsa, qurilma ko'proq quvvat sarflaydi va yuqori suv harorati ishlab chiqarish uchun ko'proq vaqt talab etadi. Natijada energiya sarfi oshadi va energiya samaradorligi koeffitsienti pasayadi.