CGK030V3L-D; CGK040V3L-D; CGK050V3L-D; CGK060V3L-D; CGK070V3L-D; CGK-060V3L-D; CGK-070V3L-D; CGK-080V3L-D; CGK-101V3L-D; CGK-130V3L-D
SPRSUN

Kelajak uchun yashil isitish yechimi sifatida SPRSUNheat nasoslari qishda qulay isitish, yozda sovutish, yumshoq havo oqimi va umumiy qulayroq hissiyotni ta'minlaydi, shu bilan birga 24 soatlik issiq suv ta'minotini qo'llab-quvvatlaydi.


R32 sovutgichi ekologik toza sovutgich bo'lib, past global isish potentsiali va ozon qatlamini yo'q qilish potentsialiga ega. Issiqlik nasosi tizimlarida R32 sovutgichdan foydalanish operatsion unumdorlik va samaradorlikni oshirishi, energiya sarfini va uglerod chiqindilarini kamaytirishi va barqaror rivojlanishning asosiy elementiga aylanishi mumkin. Sprsun tomonidan ishlab chiqilgan aqlli boshqaruv tizimi va mukammal mahsulot dizayni bilan birgalikda R32 sovutgichining afzalliklari barqaror rivojlanishga hissa qo'shish uchun to'liq foydalaniladi.

Rangli aqlli sensorli ekran nafaqat zamonaviy va zamonaviy ko'rinishga ega, balki tez javob beradi va bir tegish bilan oson sozlash uchun bir nechta rejimlarni qo'llab-quvvatlaydi, bu esa foydalanuvchilarning tizimni boshqarishini osonlashtiradi.
SPRSUNning o'zi ishlab chiqqan aqlli boshqaruv tizimi yuqori darajada integratsiyalashgan boshqaruv funktsiyalari bilan jihozlangan bo'lib, ular masofaviy APP orqali boshqarilishi mumkin. Tizimni boshqarish oson, ishlashi barqaror va haqiqatan ham odam-mashinani ajratishni amalga oshiradigan aqlli operatsion tizimdir.

Mobil telefon ilovasi va kompyuter fonida foydalanuvchilarga ochilishi mumkin. Bundan tashqari, mahalliy dilerlar aqlli ma'lumotlar platformasidan foydalanuvchilarga mahsulotni masofaviy tekshirishni ta'minlash, muammolarni hal qilishda qulay va tezkor yordam berish uchun foydalanishlari mumkin.


SPRSUN innovatsion EVI DC inverter texnologiyasi DC inverter kompressorlari va kontrollerlaridan foydalanadi va tizimning umumiy ish sxemasini optimallashtirish orqali past haroratli muhitda isitish quvvatini sezilarli darajada yaxshilaydi. Bu SPRSUN issiqlik nasoslariga uyni -30°C gacha samarali isitish imkonini beradi.

Havodan suvga issiqlik nasoslarining ushbu seriyasi yuqori sifatli komponentlar bilan ishlab chiqilgan va barqaror ishlash va uzoq muddatli ishonchlilikni ta'minlash uchun qattiq ishlab chiqarish va sinov protokollaridan o'tadi.

Eslatma:
1. Iltimos, talabingizga ko'ra to'g'ri rejimlarni tanlang, keyin uni o'rnatish sxemasiga muvofiq o'rnating. Agar faqat issiq suv funktsiyasi kerak bo'lsa, iltimos, isitish + issiq suv rejimini tanlang va keyin issiq suv sensorini issiq suv idishiga joylashtiring.
2. Ikki tomonlama valf va BV valfi o'rnatish uchun ixtiyoriy. Agar siz turli zonalarda haroratni nazorat qilishingiz kerak bo'lsa, ikkalasini ham o'rnating.
3. Fan bobini ikkilamchi aylanma nasos bilan bog'lash orqali boshqarilishi mumkin. Shu bilan birga, passiv ulanish termostati o'rnatilishi kerak.

3-in-1 funksionalligi
Yil davomida isitish, sovutish va maishiy issiq suv uchun bitta qurilma.
60°C Maks. Chiqish suvi
Har qanday uy uchun ko'p qirrali isitish echimlarini taklif qiluvchi radiatorlar va sanitariya-issiq suv uchun mos keladigan yuqori suv haroratiga erishing.
Yuqori energiya samaradorligi
ErP A+++, ilg'or invertor texnologiyasi maksimal energiya tejash va past operatsion xarajatlarni ta'minlaydi va yil davomida ekologik qulaylikni ta'minlaydi.
-30°C Barqaror ishlaydigan muhit
Hatto -30°C gacha sovuq iqlim sharoitida ham ishonchli isitishni ta'minlash uchun ishlab chiqilgan va sizga eng kerak bo'lganda qulaylikni ta'minlaydi.
IoT bulutli platformasi
Bulutli platformamiz orqali masofadan turib nazorat qilish va boshqarish — real vaqtda maʼlumotlar, aqlli rejalashtirish va ishlash haqidagi maʼlumotlar sizning qoʻlingizda boʻlsa, istalgan vaqtda va istalgan joyda aloqada boʻling.
OTA yangilanishlari
Tizimingizni havodan mikrodastur yangilanishlari bilan kelajakka moslashtiring - texnik tashrif buyurmasdan avtomatik ravishda yangi xususiyatlar va yaxshilanishlarni oling.
Smart Control/5 dyuymli sensorli displey
APP masofadan boshqarish pulti va intuitiv sensorli interfeysi oson ishlash uchun ekrandagi aniq fikr-mulohaza bilan sozlamalarni kuzatish va sozlashni osonlashtiradi.
8 birlik Kaskad funktsiyasi
Kaskad tizimida sakkiztagacha birliklarni ulash orqali isitish quvvatini osongina kengaytiring, bu kattaroq turar-joy yoki tijorat ilovalari uchun ideal.
Intelligent muzdan tushirish
Aqlli defrost mantig'i muzdan tushirish davrlarini va davomiyligini minimallashtiradi, hatto sovuqqa moyil bo'lgan sharoitlarda ham samaradorlik va qulaylikni saqlaydi.
SG tayyor
Energiyadan foydalanishni optimallashtirish uchun aqlli tarmoq signallari bilan mos keladi - qayta tiklanadigan energiya mavjudligi yoki elektr energiyasiga arzonroq tariflar asosida avtomatik ravishda ishni sozlash.

| Model | CGK030V3L-D | CGK040V3L-D | CGK050V3L-D | CGK060V3L-D | CGK070V3L-D | CGK-060V3L-D | CGK-070V3L-D | CGK-080V3L-D | CGK-101V3L-D | CGK-130V3L-D | ||||||||||||||||||||||
| Quvvat manbai / sovutgich | V/Hz/Ph | 220-240/50/1 - R32 | 220-240/50/1 - R32 | 220-240/50/1 - R32 | 220-240/50/1 - R32 | 220-240/50/1 - R32 | 380-420/50/3 - R32 | 380-420/50/3 - R32 | 380-420/50/3 - R32 | 380-420/50/3 - R32 | 380-420/50/3 - R32 | |||||||||||||||||||||
| Maks. Isitish quvvati (A7℃/W35℃) | kVt | 9.0 | 12.0 | 15.0 | 18.0 | 21.0 | 18.0 | 21.0 | 24.0 | 30.0 | 39.0 | |||||||||||||||||||||
| COP (A7℃/W35℃) | W/W | 4.35 | 4.35 | 4.33 | 4.35 | 4.32 | 4.35 | 4.33 | 4.32 | 4.15 | 4.17 | |||||||||||||||||||||
| Isitish quvvati Min./Maks.(A7℃/W35℃) | kVt | 4.14 | / | 9.00 | 5.52 | / | 12.00 | 6.90 | / | 15.00 | 8.28 | / | 18.00 | 9.66 | / | 21.00 | 8.28 | / | 18.00 | 9.66 | / | 21.00 | 11.04 | / | 24.00 | 13.80 | / | 30.00 | 17.94 | / | 39.00 | |
| Isitish quvvati Kirish Min./Maks.(A7℃/W35℃) | V | 761 | / | 2069 | 1015 | / | 2759 | 1275 | / | 3464 | 1523 | / | 4138 | 1789 | / | 4861 | 1523 | / | 4138 | 1785 | / | 4850 | 2044 | / | 5556 | 2660 | / | 7229 | 3442 | / | 9353 | |
| COP Min./Maks.(A7℃/W35℃) | W/W | 4.35 | / | 5.44 | 4.35 | / | 5.44 | 4.33 | / | 5.41 | 4.35 | / | 5.44 | 4.32 | / | 5.40 | 4.35 | / | 5.44 | 4.33 | / | 5.41 | 4.32 | / | 5.40 | 4.15 | / | 5.19 | 4.17 | / | 5.21 | |
| Maks. Isitish quvvati (A7℃/W45℃) | kVt | 8.9 | 11.8 | 14.8 | 17.7 | 20.7 | 17.7 | 20.7 | 23.6 | 29.6 | 38.4 | |||||||||||||||||||||
| COP (A7℃/W45℃) | W/W | 3.35 | 3.35 | 3.33 | 3.35 | 3.33 | 3.35 | 3.33 | 3.33 | 3.20 | 3.21 | |||||||||||||||||||||
| Isitish quvvati Min./Maks.(A7℃/W45℃) | kVt | 4.08 | / | 8.87 | 5.44 | / | 11.82 | 6.80 | / | 14.78 | 8.16 | / | 17.73 | 9.52 | / | 20.69 | 8.16 | / | 17.73 | 9.52 | / | 20.69 | 10.87 | / | 23.64 | 13.59 | / | 29.55 | 17.67 | / | 38.42 | |
| Isitish quvvati minimal/maks.(A7℃/W45℃) | V | 974 | / | 2647 | 1299 | / | 3529 | 1631 | / | 4431 | 1948 | / | 5293 | 2288 | / | 6218 | 1948 | / | 5293 | 2283 | / | 6204 | 2615 | / | 7107 | 3403 | / | 9247 | 4403 | / | 11964 | |
| COP Min./Maks.(A7℃/W45℃) | W/W | 3.35 | / | 4.19 | 3.35 | / | 4.19 | 3.33 | / | 4.17 | 3.35 | / | 4.19 | 3.33 | / | 4.16 | 3.35 | / | 4.19 | 3.33 | / | 4.17 | 3.33 | / | 4.16 | 3.20 | / | 3.99 | 3.21 | / | 4.01 | |
| Maks. Sovutish quvvati (A35 ℃/W18 ℃) | kVt | 8.3 | 11.1 | 13.9 | 16.7 | 18.1 | 16.7 | 18.1 | 20.9 | 25.0 | 33.4 | |||||||||||||||||||||
| EER (A35℃/W18℃) | W/W | 3.63 | 3.63 | 3.63 | 3.66 | 3.63 | 3.66 | 3.63 | 3.64 | 3.63 | 3.63 | |||||||||||||||||||||
| Sovutish quvvati Min./Maks.(A35℃/W18℃) | kVt | 3.84 | / | 8.34 | 5.12 | / | 11.12 | 6.39 | / | 13.90 | 7.67 | / | 16.68 | 8.31 | / | 18.07 | 7.67 | / | 16.68 | 8.31 | / | 18.07 | 9.59 | / | 20.85 | 11.51 | / | 25.02 | 15.35 | / | 33.36 | |
| Kirish quvvati sovutish min./maks.(A35℃/W18℃) | V | 895 | / | 2297 | 1194 | / | 3062 | 1492 | / | 3828 | 1777 | / | 4559 | 1940 | / | 4976 | 1777 | / | 4559 | 1940 | / | 4976 | 2230 | / | 5720 | 2686 | / | 6890 | 3581 | / | 9186 | |
| EER Min./Maks.(A35℃/W18℃) | W/W | 3.63 | / | 4.29 | 3.63 | / | 4.29 | 3.63 | / | 4.29 | 3.66 | / | 4.32 | 3.63 | / | 4.29 | 3.66 | / | 4.32 | 3.63 | / | 4.29 | 3.64 | / | 4.30 | 3.63 | / | 4.29 | 3.63 | / | 4.29 | |
| Maks. Sovutish quvvati (A35 ℃/W7 ℃) | kVt | 6.0 | 8.0 | 10.0 | 12.0 | 13.0 | 12.0 | 13.0 | 15.0 | 18.0 | 24.0 | |||||||||||||||||||||
| EER(A35℃/W7℃) | W/W | 2.70 | 2.70 | 2.70 | 2.72 | 2.70 | 2.72 | 2.70 | 2.71 | 2.70 | 2.70 | |||||||||||||||||||||
| Sovutish quvvati Min./Maks.(A35℃/W7℃) | kVt | 2.76 | / | 6.00 | 3.68 | / | 8.00 | 4.60 | / | 10.00 | 5.52 | / | 12.00 | 5.98 | / | 13.00 | 5.52 | / | 12.00 | 5.98 | / | 13.00 | 6.90 | / | 15.00 | 8.28 | / | 18.00 | 11.04 | / | 24.00 | |
| Sovutish uchun kirish quvvati Min./Maks.(A35℃/W7℃) | V | 741 | / | 2222 | 988 | / | 2963 | 1235 | / | 3704 | 1471 | / | 4412 | 1605 | / | 4815 | 1471 | / | 4412 | 1605 | / | 4815 | 1845 | / | 5535 | 2222 | / | 6667 | 2963 | / | 8889 | |
| EER Min./Maks.(A35℃/W7℃) | W/W | 2.70 | / | 3.73 | 2.70 | / | 3.73 | 2.70 | / | 3.73 | 2.72 | / | 3.75 | 2.70 | / | 3.73 | 2.72 | / | 3.75 | 2.70 | / | 3.73 | 2.71 | / | 3.74 | 2.70 | / | 3.73 | 2.70 | / | 3.73 | |
| Suv oqimi | m3/soat | 1.55 | 2.06 | 2.58 | 3.10 | 3.61 | 3.10 | 3.61 | 4.13 | 5.16 | 6.71 | |||||||||||||||||||||
| Maksimal quvvat kiritish | kVt | 4.00 | 5.00 | 5.80 | 6.80 | 7.80 | 7.00 | 8.00 | 9.00 | 12.00 | 15.00 | |||||||||||||||||||||
| Maksimal oqim | A | 20.00 | 25.00 | 27.00 | 32.00 | 36.00 | 14.00 | 16.00 | 18.00 | 24.00 | 27.00 | |||||||||||||||||||||
| Tel diametri | mm² | 4.0 | 6.0 | 6.0 | 6.0 | 10.0 | 4.0 | 6.0 | 6.0 | 6.0 | 6.0 | |||||||||||||||||||||
| Sug'urta yoki o'chirgich | A | 25A | 32A | 32A | 40A | 63A | 20A | 25A | 25A | 32A | 32A | |||||||||||||||||||||
| Kompressor | Turi - Miqdor/tizim | Egizak aylanish - 1 | Egizak aylanish - 1 | Egizak aylanish - 1 | Egizak aylanish - 1 | Egizak aylanish - 1 | Egizak aylanish - 1 | Egizak aylanish - 1 | Egizak aylanish - 1 | Egizak aylanish - 1 | Egizak aylanish - 1 | |||||||||||||||||||||
| Muxlis | Miqdori | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | |||||||||||||||||||||
| Havo oqimi | m3/soat | 3000 | 4000 | 5000 | 6000 | 7000 | 6000 | 7000 | 8000 | 10000 | 13000 | |||||||||||||||||||||
| Nominal quvvat | V | 120 | 150 | 150 | 160 | 170 | 160 | 170 | 180 | 300 | 330 | |||||||||||||||||||||
| Suv tomonidagi issiqlik almashtirgich | Turi | Plastinkali issiqlik almashtirgich | Plastinkali issiqlik almashtirgich | Plastinkali issiqlik almashtirgich | Plastinkali issiqlik almashtirgich | Plastinkali issiqlik almashtirgich | Plastinkali issiqlik almashtirgich | Plastinkali issiqlik almashtirgich | Plastinkali issiqlik almashtirgich | Plastinkali issiqlik almashtirgich | Plastinkali issiqlik almashtirgich | |||||||||||||||||||||
| Suv bosimining pasayishi | kPa | 26 | 18 | 20 | 26 | 28 | 26 | 28 | 25 | 28 | 33 | |||||||||||||||||||||
| Quvurlar ulanishi | dyuym | G1' | G1' | G1' | G1' | G1' | G1' | G1' | G1' | G1-1/4' | G1-1/4' | |||||||||||||||||||||
| Ruxsat etilgan suv oqimi | Min./Reyting./Maks. | L/S | 0.26 | 0.42 | 0.71 | 0.35 | 0.56 | 0.94 | 0.44 | 0.71 | 1.18 | 0.53 | 0.85 | 1.41 | 0.62 | 0.99 | 1.65 | 0.53 | 0.85 | 1.41 | 0.62 | 0.99 | 1.65 | 0.72 | 1.15 | 1.91 | 0.90 | 1.43 | 2.39 | 1.16 | 1.86 | 3.10 |
| Ovoz bosimi darajasi (1 m) | dB(A) | 42~51,2 | 44,2 ~ 54,7 | 46,2 ~ 56,7 | 44,6 ~ 57,5 | 48,3 ~ 58,2 | 44,6 ~ 57,5 | 48,3 ~ 58,2 | 51,2 ~ 60,6 | 52,2 ~ 62,6 | 53,2 ~ 63,6 | |||||||||||||||||||||
| Ovoz kuchi darajasi (1m) | dB(A) | 61.5 | 62.5 | 64.5 | 68.8 | 70.8 | 68.8 | 70.8 | 72.5 | 74 | 75 | |||||||||||||||||||||
| Aniq oʻlcham (L×D×H) | mm | 1043×480×840 | 1043×480×840 | 965×450×1370 | 965×450×1370 | 965×450×1370 | 965×450×1370 | 965×450×1370 | 965×450×1370 | 1070×480×1560 | 1070×480×1560 | |||||||||||||||||||||
| Karton qadoqlash o'lchami (L × D × H) | mm | 1155×511×990 | 1155×511×990 | 1020×464×1500 | 1020×464×1500 | 1020×464×1500 | 1020×464×1500 | 1020×464×1500 | 1020×464×1500 | 1155×511×1710 | 1155×511×1710 | |||||||||||||||||||||
| Splint qadoqlash o'lchami (L × D × H) | mm | |||||||||||||||||||||||||||||||
| Sof og'irlik | kg | 67 | 75 | 102 | 103 | 106 | 103 | 106 | 111 | 146 | 157 | |||||||||||||||||||||
| Kartonning yalpi og'irligi | kg | 82 | 101 | 118 | 119 | 122 | 119 | 122 | 127 | 163 | 174 | |||||||||||||||||||||
| Splintning yalpi og'irligi | kg | |||||||||||||||||||||||||||||||
| Eslatma: (1) Isitish holati: suv kirish/chiqish harorati: 30℃/35℃, Atrof-muhit harorati: JB 7℃/WB 6℃; | ||||||||||||||||||||||||||||||||
| (2) Isitish holati: suv kirish / chiqish harorati: 40 ℃/45 ℃, Atrof-muhit harorati: JB 7 ℃ / WB 6 ℃; | ||||||||||||||||||||||||||||||||
| (3) Sovutish holati: suv kirish / chiqish harorati: 23 ℃ / 18 ℃, Atrof-muhit harorati: DB35 ℃ / WB24 ℃; | ||||||||||||||||||||||||||||||||
| (4) Sovutish holati: suv kirish / chiqish harorati: 12 ℃/7 ℃, Atrof-muhit harorati: DB35 ℃ / WB24 ℃; | ||||||||||||||||||||||||||||||||