SKU: | |
---|---|
Availability: | |
CGK/C-12(LBP)
SPRSUN
Our low temperature EVI inverter air source heat pumps are designed for house heating and cooling in cold weather where lowest air temperature reaches -30℃. They have the following important features:
Low Ambient Temperature (-30℃~45℃) :
Because of the Enhanced Vapour Injection (EVI) technology rotary compressor, EVI air source heat pump can work stably in the low temperature condition.
Improved Heating Efficiency:
When the temperature reaches the set value, it will automatically change to low frequency operation mode, and the effect of energy saving is remarkable.
Reduced Defrosting Time:
The frequency converter enables the EVI inverter air source heat pump to automatically adjust the compressor operating frequency according to the ambient temperature. When the unit needs defrosting, it will use high frequency operation, which greatly reduces the defrosting time and thus improves the heating efficiency.
Constant Indoor Temperature:
SPRSUN EVI inverter heat pumps can operate in the range of 30Hz to 70Hz, output and utilize heat energy according to the environment and the set temperature. Inverter heat pumps can maintain the set temperature with a lower operating frequency after reaching the set temperature and will not frequently start or turn off.
Rated Working Condition:
Heating: air temperature (DB/WB): 7℃/6℃, water temperature (inlet/outlet): 40℃/45℃;
Cooling: air temperature (DB/WB): 35℃, wet-bulb temp: 24℃, water temperature (inlet/outlet): 12℃/7℃.
Model | CGK/C-12(LBP) | CGK/C-18(LBP) | CGK/C-22(LBP) | |
Power Supply | V | 220V~240V/50Hz or 60Hz/1ph | ||
Heating Capacity | KW | 9.5 | 16 | 18 |
Input Power | KW | 2.75 | 4.62 | 5.26 |
COP | 3.45 | 3.46 | 3.42 | |
Cooling Capacity | KW | 7.2 | 12.0 | 14.0 |
Input Power of Cooling | KW | 2.85 | 4.71 | 5.58 |
EER | 2.53 | 2.55 | 2.51 | |
Rated Current | A | 13.9 | 23.4 | 26.6 |
Fan Motor Power | W | 65 | 65*2 | 65*2 |
Fan Motor Quantity | Piece | 1 | 2 | 2 |
Water Flow | L/h | 1634 | 2752 | 3095 |
Water Pressure Drop | Kpa | ≤30 | ≤40 | ≤45 |
Net Weight | kg | 90 | 140 | 145 |
Gross Weight | kg | 99 | 154 | 160 |
Noise | db | 52 | 56 | 58 |
Waterproof Grade | IPX4 | |||
Electric Shock Proof Grade | I | |||
Pipe Size (Internal Thread) | mm | 25 | 25 | 32 |
Dimension | mm | 1206*475*968 | 1030*480*1330 | 1030*480*1330 |
Packing Dimension | mm | 1270*500*1120 | 1090*500*1480 | 1090*500*1480 |
It is easy to install SPRSUN EVI inverter air source heat pumps as shown by the following Installation Diagram:
Related EVI inverter heat pumps are as follows:
Our low temperature EVI inverter air source heat pumps are designed for house heating and cooling in cold weather where lowest air temperature reaches -30℃. They have the following important features:
Low Ambient Temperature (-30℃~45℃) :
Because of the Enhanced Vapour Injection (EVI) technology rotary compressor, EVI air source heat pump can work stably in the low temperature condition.
Improved Heating Efficiency:
When the temperature reaches the set value, it will automatically change to low frequency operation mode, and the effect of energy saving is remarkable.
Reduced Defrosting Time:
The frequency converter enables the EVI inverter air source heat pump to automatically adjust the compressor operating frequency according to the ambient temperature. When the unit needs defrosting, it will use high frequency operation, which greatly reduces the defrosting time and thus improves the heating efficiency.
Constant Indoor Temperature:
SPRSUN EVI inverter heat pumps can operate in the range of 30Hz to 70Hz, output and utilize heat energy according to the environment and the set temperature. Inverter heat pumps can maintain the set temperature with a lower operating frequency after reaching the set temperature and will not frequently start or turn off.
Rated Working Condition:
Heating: air temperature (DB/WB): 7℃/6℃, water temperature (inlet/outlet): 40℃/45℃;
Cooling: air temperature (DB/WB): 35℃, wet-bulb temp: 24℃, water temperature (inlet/outlet): 12℃/7℃.
Model | CGK/C-12(LBP) | CGK/C-18(LBP) | CGK/C-22(LBP) | |
Power Supply | V | 220V~240V/50Hz or 60Hz/1ph | ||
Heating Capacity | KW | 9.5 | 16 | 18 |
Input Power | KW | 2.75 | 4.62 | 5.26 |
COP | 3.45 | 3.46 | 3.42 | |
Cooling Capacity | KW | 7.2 | 12.0 | 14.0 |
Input Power of Cooling | KW | 2.85 | 4.71 | 5.58 |
EER | 2.53 | 2.55 | 2.51 | |
Rated Current | A | 13.9 | 23.4 | 26.6 |
Fan Motor Power | W | 65 | 65*2 | 65*2 |
Fan Motor Quantity | Piece | 1 | 2 | 2 |
Water Flow | L/h | 1634 | 2752 | 3095 |
Water Pressure Drop | Kpa | ≤30 | ≤40 | ≤45 |
Net Weight | kg | 90 | 140 | 145 |
Gross Weight | kg | 99 | 154 | 160 |
Noise | db | 52 | 56 | 58 |
Waterproof Grade | IPX4 | |||
Electric Shock Proof Grade | I | |||
Pipe Size (Internal Thread) | mm | 25 | 25 | 32 |
Dimension | mm | 1206*475*968 | 1030*480*1330 | 1030*480*1330 |
Packing Dimension | mm | 1270*500*1120 | 1090*500*1480 | 1090*500*1480 |
It is easy to install SPRSUN EVI inverter air source heat pumps as shown by the following Installation Diagram:
Related EVI inverter heat pumps are as follows:
Our experienced engineering team provides good support for any questions concerning the products and installation before, during and after products are sold.
Before Selling
Set up customers file and arrange professional sales engineers to introduce company products and services to customers in details.
If customers are interested in our products, we will send professional technicians to survey the installation environment.
Provide solutions according to different customers' requirements.
During Selling
Machine installed and tested by QA engineers.
Ensure all the products we provide are qualified and new. The working life of the main engine is 15 years.
Construct and install the heat pump according to national relevant policies strictly and ensure high quality delivery on time.
Test and debug the equipments strictly to ensure the safety and stability.
During the delivery, provide comprehensive and professional technical training on instructions and maintenance to customers.
After Selling
We promise to offer free consulting call in 7×24 hours mode to solve the problems found in practice. The number is 86-20-82181867.
Sprsun offers 18-month long warranty. Within 18 months since the delivery date, if the product has any failure under normal usage, Sprsun will provide free assembly parts.
After the expiration of the warranty period, we will continue to provide lifelong maintenance services, with just a small amount of charges.
Our experienced engineering team provides good support for any questions concerning the products and installation before, during and after products are sold.
Before Selling
Set up customers file and arrange professional sales engineers to introduce company products and services to customers in details.
If customers are interested in our products, we will send professional technicians to survey the installation environment.
Provide solutions according to different customers' requirements.
During Selling
Machine installed and tested by QA engineers.
Ensure all the products we provide are qualified and new. The working life of the main engine is 15 years.
Construct and install the heat pump according to national relevant policies strictly and ensure high quality delivery on time.
Test and debug the equipments strictly to ensure the safety and stability.
During the delivery, provide comprehensive and professional technical training on instructions and maintenance to customers.
After Selling
We promise to offer free consulting call in 7×24 hours mode to solve the problems found in practice. The number is 86-20-82181867.
Sprsun offers 18-month long warranty. Within 18 months since the delivery date, if the product has any failure under normal usage, Sprsun will provide free assembly parts.
After the expiration of the warranty period, we will continue to provide lifelong maintenance services, with just a small amount of charges.